SikaQuick® Pro VOH
SikaQuick® Pro VOH is a fast setting, one component, easy to use repair mortar for vertical and overhead applications on concrete and mortar surfaces.
- Fiber reinforced & polymer modified
- Contains corrosion inhibitors
- Apply up to 3" on vertical surfaces in one layer
- Overhead application up to 2"
- High early & ultimate strength
- High bond strength ensures excellent adhesion
- Easy to use - Just add water
- Fast finishing time
- Minimal wait time between layers
- Suitable for interior & exterior applications
- Increased freeze/thaw durability & resistance to deicing salts
Usage
- Quick repairs to vertical & overhead surfaces on grade, above and below grade
- As a structural repair material for:
- Driveways / Patios / Steps / Basements / Balconies / Foundations
- A fast setting material for new construction defects
Advantages
- Fiber reinforced & polymer modified
- Contains corrosion inhibitors
- Apply up to 3" on vertical surfaces in one layer
- Overhead application up to 2"
- High early & ultimate strength
- High bond strength ensures excellent adhesion
- Easy to use - Just add water
- Fast finishing time
- Minimal wait time between layers
- Suitable for interior & exterior applications
- Increased freeze/thaw durability & resistance to deicing salts
Packaging
44 lb. bag
Color
Gray powder
Product Details
Shelf Life
12 months from date of production if stored properly in original, unopened and undamaged sealed packaging.
Storage Conditions
Store dry at 40–95°F (4–35°C)
Protect from moisture. If damp, discard material.
Compressive Strength
| 73°F (23°C) | |
| 3 hours | > 1,500 psi (10.3 MPa) |
| 1 day | > 3,000 psi (20.7 MPa) |
| 7 days | > 4,500 psi (31.0 MPa) |
| 28 days | > 5,500 psi (37.9 MPa) |
Modulus of Elasticity in Compression
| 7 days | 2.2x106 psi (15.2 GPa) |
Flexural Strength
| 1 day | 400 psi (2.8 MPa) |
| 7 days | 600 psi (4.1 MPa) |
| 28 days | 1,000 psi (6.9 MPa) |
Pull-Out Resistance
| > 250 psi (1.7 MPa) Substrate failure | (ASTM C-1583) 73°F (23°C) 50% R.H. |
Shrinkage
| < 0.05 % | (ASTM C-157 modified per ASTM C-928) |
Rapid Chloride Permeability
| 28 days | Low range |
Slant Shear Strength
| 1 day | 1,000 psi (6.9 MPa) |
| 7 days | 1,600 psi (11.0 MPa) |
| 28 days | 2,000 psi (13.8 MPa) |
*Mortar scrubbed into substrate at 73 °F (23 °C) and 50 % R.H.
Splitting tensile strength
| 1 day | 200 psi (1.4 MPa) |
| 7 days | 250 psi (1.7 MPa) |
| 28 days | 500 psi (3.4 MPa) |
Application
Mixing Ratio
6-6.5 pints per bag
Layer Thickness
| Min. | Max. | |
| Overhead | 1/8" | 2" |
| Vertical | 1/8" | 3" |
Product Temperature
65 - 75°F
Ambient Air Temperature
> 45°F
Substrate Temperature
> 45°F
Application Time
≈ 15 minutes
Waiting Time
| Time between layers | Final set time |
| Acrylic water based coating | 4 hrs |
| Epoxy/PU based coating | 6 hrs |
*Compatibility and adhesion testing is always recommended before coating.
Set Time
| 10-12 minutes | (ASTM C-266) |
Final set time
| < 35 min | (ASTM C-266) |
*To control setting time, cold water should be used in hot weather and hot water should be used in cold weather.
Finishing time
20-30 minutes
Fresh mortar density
| 125 lb/ft3 | (ASTM C-138) |
Coverage
0.44 ft3 per bag
Coverage figures do not include allowance for surface profile and porosity or material waste
SURFACE PREPARATION
- Surface must be clean, sound and free of frost.
- Remove all deteriorated concrete, dirt, oil, grease, and other bond-inhibiting materials from the area to be repaired.
- Preparation work should be done by high pressure water blast, scabbling or other appropriate mechanical means to obtain an exposed aggregate surface profile of ±1/16" (1.6 mm) (CSP-5). To ensure optimum repair results, the effectiveness of decontamination and preparation should be assessed by a pull-off test.
- Saw cutting of edges is preferred and a dovetail is recommended.
- Substrate should be Saturated Surface Dry (SSD) with clean water prior to application. No standing water should remain during application.
PRIMING
- Reinforcing steel: Steel reinforcement should be thoroughly prepared by mechanical cleaning to remove all traces of rust. Where corrosion has occured due ro the presence of chlorides, the steel should be high pressure washed with clean water after mechanical cleaning. For priming of reinforcing steel use Sika® Armatec® 110 EpoCem (consult PDS).
- Concrete substrate: A scrub coat of SikaQuick® Pro VOH can be applied prior to placement of the mortar. The repair mortar must be applied into the wet scrub coat before it dries.
MIXING
- Wet down all tools and mixer to be used.
- Mix mechanically with a low-speed drill (400–600 rpm) and mixing paddle or mortar mixer.
- Mix to a uniform consistency, maximum 3 minutes.
- Manual mixing can be tolerated only for less than a full bag.
- Thorough mixing and proper proportioning of the powder and liquid is necessary.
- Inaccurate proportioning of the powder to liquid will result in a finished product that may not conform to the typical published performance property values.
With Water
- Start mixing with 6 pints (2.8 L) of water per bag.
- Adjust the water dosage by a maximum amount of ± ½ pint, if necessary, to achieve the desired consistency.
- Do not over-water. Over-watering may result in difficulty handling and/or not meeting stated property values.
With SikaLatex® R
- Start mixing with 6 pints (2.8 L) of Sika Latex® R per bag.
- Adjust the SikaLatex® R dosage by a maximum amount of ± ½ pint, if necessary, to achieve the desired consistency.
- Do not overdose with SikaLatex® R. Using too much SikaLatex®-R may result in difficulty handling and/or not meeting typical published performance property values.
APPLICATION
- The mixed SikaQuick® Pro VOH must be worked well into the prepared substrate, filling all pores and voids.
- Compact well. Force material against edge of repair working towards the center. Thoroughly compact the mortar around exposed reinforcement.
- After filling repair, consolidate, then screed.
- Finish with steel, magnesium, wood, plastic floats, or damp sponges, depending on the desired surface texture.
MULTIPLE LIFTS
- Where multiple lifts are required, score top surface on each lift to produce a roughened substrate for next lift.
- Allow preceding lift to harden and achieve initial set before applying fresh material.
- SSD previous lift by lightly misting with clean water. Remove all standing droplets.
- Repeat procedure until desired installation thickness is achieved. Finish the final lift of SikaQuick® Pro VOH as described above.
- If previous layers are over 6 hours old, mechanically prepare the substrate and dampen.
CURING TREATMENT
Proper curing is critical for sound results. Curing means maintaining proper moisture.
- Covering the material with polyethylene (plastic) sheeting is a sufficient way to help retain moisture. Place plastic as soon as the material has set (lost it's sheen).
- If surface begins to appear dry remove the plastic and sufficiently moisten the surface and replace the plastic.
- Protect freshly applied mortar form direct sunlight, wind, rain and frost.
CLEANING OF TOOLS
- Uncured product may be cleaned from tools and surfaces with water.
- Cured product must be removed mechanically.