Sika® Injection-307
Polyacrylic elastic injection resin for permanent watertight sealing
0.0 (0)
Sika® Injection-307 is a polyacrylic, 3-part acrylate based injection resin with a very low viscosity and adjustable reaction time
- Provides a passivating environment for embedded steel reinforcement
- Adjustable curing time between 10 and 50 minutes
- Permanently elastic
- Capable of reversibly absorbing (swelling) and releasing (shrinking) moisture
- Very low viscosity comparable to water
- After curing the Product is insoluble in water and hydrocarbons and resistant to alkalis
Usage
The Product is designed for:- Crack and joint injection
- Injection of SikaFuko® injection hoses to seal construction joints
- Sealing water-bearing cracks and voids
- Sealing all types of leaking building components in damp or water saturated ground conditions
- Sealing leaks where there is some minor movement
- Sealing drainage pipe joints, that are covered with damp or water saturated soil
- Injection repair of damaged waterproofing membranes (single and double layer systems)
Advantages
- Provides a passivating environment for embedded steel reinforcement
- Adjustable curing time between 10 and 50 minutes
- Permanently elastic
- Capable of reversibly absorbing (swelling) and releasing (shrinking) moisture
- Very low viscosity comparable to water
- After curing the Product is insoluble in water and hydrocarbons and resistant to alkalis
Packaging
Ready to use kit
Part A (Resin) | 2 × 9.6 kg container |
Part A1 (Accelerator) | 1 × 1.05 kg container |
Part B (Hardener) | 2 × 0.8 kg container |
Alternative Pallet Set (equivalent to 36 × ready-to-use-kits):
Part A (Resin) | 36 × 19.2 kg container |
Part A1 (Accelerator) | 36 × 1.05 kg container |
Part B (Hardener) | 72 × 0.8 kg container |
Refer to the current price list for available packaging variations.
Color
Part A (Resin) | Blue transparent - liquid |
Part A1 (Accelerator) | Yellow transparent - liquid |
Part B (Hardener) | White powder |
Product Details
APPROVALS / STANDARDS
CE marking and declaration of performance based on EN 1504-5:2004 Products and systems for the protection and repair of concrete structures — Concrete injection
Water Tightness Building Regulations List A, SikaFuko® VT-1, WISSBAU, Test repor
Chemical Base
3-part polyacrylic resin
Shelf Life
12 months from date of production
Storage Conditions
The product must be stored in original, unopened and undamaged sealed packaging in dry conditions at temperatures between +10 °C and +30 °C. Protect Part B from frost. Always refer to packaging.
Refer to the current Safety Data Sheet for information on safe handling and storage.
Density
Part A (Resin) | 1.073 kg/l |
Part A1 (Accelerator) | 1.040 kg/l |
Part B (Hardener) | 2.100 kg/l |
Viscosity
3.8 mPa∙s (complete mixture +20 °C) | (EN ISO 3219) |
Application
Mixing Ratio
Accelerator metering chart by ambient temperature per 9.6 kg of Part A resin.
Reaction time | +5 °C (+41 °F) | +15 °C (+59 °F) | +22 °C (+72 °F) | +30 °C (+86 °F) | +40 °C (+104 °F) |
10 min | 1170 ml | 650 ml | 440 ml | 360 ml | 250 ml |
20 min | 750 ml | 440 ml | 340 ml | 290 ml | 200 ml |
30 min | 590 ml | 390 ml | 290 ml | 250 ml | 170 ml |
40 min | 550 ml | 350 ml | 260 ml | 230 ml | 160 ml |
50 min | 520 ml | 330 ml | 230 ml | 210 ml | 140 ml |
The Accelerator is diluted in water so that the total Accelerator solution is 1000 ml.
Example of a mix calculation for ~ 20 litres of mixed resin.
Ambient temperature | +22 °C (+72 °F) |
Required reaction time | 30 min |
Part A | 9.6 kg |
Accelerator solution (Part A1 + water) | 290 ml Accelerator 710 ml water |
Part B solution | 0.8 kg dissolved in 10 L of water |
Product Temperature
Maximum | +40 °C |
Minimum | +5 °C |
Ambient Air Temperature
Maximum | +40 °C |
Minimum | +5 °C |
Substrate Temperature
Maximum | +40 °C |
Minimum | +5 °C |
Pot Life
When using one component pumps pot life or workability is 0.8 × Reaction time. Refer to Table 1 Accelerator metering chart in the Mixing Ratio section.
Cure Time
60 minutes
Gel time
10-50 minutes
Coverage
~ 40 litres per kit
MIXING
PREPARE PART B SOLUTION
- Pour 10 litres of water in a clean container.
- Add1 bag (800 g) of Part B to the water and mix thoroughly with a low speed mixer until Part B is completely dissolved.
PREPARE ACCELERATOR SOLUTION
- Determine the required quantity of accelerator (Part A1). Refer to the Accelerator metering chart in the Mixing Ratio section.
- Dilute the selected quantity of accelerator with water to a total quantity of 1 litre accelerator solution.
MIX ACCELERATOR SOLUTION INTO PART A RESIN
- Pour the 1 litre of accelerator solution into 1 × 9.6 kg container of Part A and shake to mix thoroughly.
MIX RESIN SOLUTION AND HARDENER SOLUTION
One component pump:
- At a ratio of 1:1 by volume, pour the resin solution and hardener solution into a clean mixing container.
- Mix thoroughly with a mixer and pour into the hopper of the pump.
Two component pump:
- Pour the resin solution into the hopper of the pump`s ‘A’ side.
- Pour the hardener solution into the hopper of the pump`s ‘B’ side.
- Pump the Product at a ratio of 1:1 by volume.
APPLICATION
IMPORTANT
Environmental considerations
Failure to properly assess the jobsite and the scope of the application can lead to a loss of Product performance.
- Survey the jobsite to assess foundations and ground conditions before carrying out curtain injection in close proximity to or within existing structures.
- Check to make sure there are no open pipes or drainage systems close to injection areas.
- Prior to use check the Product's gel time within the local site ambient conditions.
- Contact Sika technical services for specific information on resistance to hydrocarbons or chemicals.
Reference must be made to further documentation where applicable, such as relevant method statements, application manuals and installation or working instructions.
Sika® Injection-307 can be used with standard one or two component injection pumps.
CLEANING OF TOOLS
Clean all tools and application equipment with water.