Sikagard®-200 Enviroseal
(formerly MProtect H 200)
CLEAR, WATER-BASED 20% SILANE REACTIVE PENETRATING SEALER
0.0 (0)
Sikagard®-200 Enviroseal is a clear, water-based 20% alkylalkoxysilane reactive penetrating sealer. It protects against moisture and chloride intrusion.
- Does not alter surface appearance
- Breathable to allow interior moisture to escape without damaging sealer
- One component -for ease of application
- Protects against damage from moisture intrusion and chloride ion penetration
Usage
- Horizontal and vertical
- Exterior or interior
- Above grade
- Concrete substrates:
- Architectural
- Exposed aggregate
- Glass-fiberreinforced
- Precast
- Cast in place/precast
- Silica fume
- Hard burnt brick
- Stucco
- Troweled/smooth
- Integrally colored
- Brick pavers
- Tile (unglazed)
Advantages
- Does not alter surface appearance
- Breathable to allow interior moisture to escape without damaging sealer
- One component -for ease of application
- Protects against damage from moisture intrusion and chloride ion penetration
Packaging
5 gallon (19 L) pails
54 gallon (205 L) drums
Color
Milky white; dries clear
Product Details
ENVIRONMENTAL INFORMATION
This product cannot be used in the South Coast Air Quality Management District (“SCAQMD”) unless the following criteria from SCAQMD Rule 1113(b)(54) are met:
(A) Used only for reinforced concrete bridge structures for transportation projects within 5 miles of the coast or above 4,000 feet elevation or for restoration and/or preservation projects on registered historical buildings that are under the purview of a restoration architect.
(B) Penetrate into concrete and masonry substrates and chemically react to form covalent bonds with naturally occurring minerals in the substrate.
(C) Line the pores of concrete and masonry substrates with a hydrophobic coating, but do not form a surface film.
(D) Improve water repellency at least 80 percent after application on a concrete or masonry substrate. This performance must be verified on standardized test specimens, in accordance with one or more of the following standards: ASTM C67, or ASTM C97/97M, or ASTM C140.
(E) Provide a breathable waterproof barrier for concrete or masonry surfaces that does not prevent or substantially retard water vapor transmission. This performance must be verified on standardized test specimens, in accordance with ASTM E96/E96M or ASTM D6490.
(F) Meet the performance criteria listed in the National Cooperative Highway Research Report 244 (1981), surface chloride screening applications, for products labeled and formulated for vehicular traffic.
Please review SCAQMD Rule 1113 for further information.
APPROVALS / STANDARDS
- USDA acceptance on nonfood-contact areas
- Alberta DOT, Type 1a
Chemical Base
water-based alkylalkoxysilane sealer.
Shelf Life
18 months when properly stored
Storage Conditions
Store in unopened containers in a clean, dry area between 35 and 110° F (2 and 43° C). Keep from freezing.
Density
8.16 lb/gal
Specific Gravity
0.98 kg/L
Flash Point
> 200 ° F (> 93 ° C) | (ASTM D 3278, SETA) |
Solid content by mass
20%
Active content
20%
Freeze Thaw De-Icing Salt Resistance
Scaling resistance rating
0–No Scaling, non-air-entrained concrete, 100 cycles treated concrete | (ASTM C 672) |
Penetration Depth
0.14 in (3.6 mm)
average depth, depending on the substrate
Rapid Chloride Permeability
Absorbed Chloride
92% reduction – exceeds criteria | (NCHRP 244 Series II-cube test) |
99% reduction – exceeds criteria | (NCHRP 244 Series IV - Southern climate) |
Water Weight Gain
86% reduction – exceeds criteria | (NCHRP 244 Series II-cube test) |
Solar Reflectance
Surface appearance after application
Unchanged | (Federal Reflectance Test Method 6121) |
Water Absorption
0.53% over 48 hours | (ASTM C 642) |
Water resistance
Water repellent performance
85.6% | (Alberta Transportation and Utilities Procedures - Type 1a) |
Application
Drying Time
Typical drying time for Sikagard®-200 Enviroseal is 4 hours at 70° F (21° C) and 50% relative humidity. Cooler temperatures or higher relative humidity can extend the drying time.
Coverage
Concrete: 100–175 ft2/gal (2.4–4.3 m2/L)
Brick: 100–175 ft2/gal (2.4–4.3 m2/L)
Stucco: 60–100 ft2/gal (1.5–2.4 m2/L)
Always apply a test area to determine actual coverage rates. Coverage rates will vary greatly with the porosity of the substrate.
APPLICATION INSTRUCTIONS
- Keep material from freezing.
- Do not dilute Sikagard®-200 Enviroseal.
- Water repellents perform best when applied to a dry substrate, when power washing is performed allow for a proper dry time before applying the water repellent.
- Do not apply during inclement weather or when inclement weather is anticipated within 12 hours.
- To prevent damage to nearby shrubbery and landscaping, cover or protect with drop cloth.
- Protect asphalt-based products such as roofing materials or plastic products from overspray.
- Sikagard®-200 Enviroseal may leave a temporary slippery surface for up to several hours after application. Therefore, do not reopen traffic-bearing surfaces until the treated surface is dry.
- Variations in the texture and porosity of the substrate will affect the coverage and performance of the product.
- Sikagard®-200 Enviroseal will not inhibit water penetration through unsound or cracked surfaces, or surfaces with defective flashing, caulking, or structural waterproofing.
- Line striping can be done after the application of the sealer.
- Make certain the most current versions of the product data sheet and SDS are being used.
- Proper application is the responsibility of the user. Field visits by Sika personnel are for the purpose of making technical recommendations only and are not for supervising or providing quality control on the jobsite.
SUBSTRATE PREPARATION
- Verify the substrate has properly cured. Concrete should obtain 80% of design strength, typically achieved within 14–28 days.
- Clean all surfaces of all sand, surface dust and dirt, oil, grease, chemical films and coatings, and other contaminants prior to application. Power wash, sandblast, or shot blast as necessary to achieve the desired surface condition.
- Air, material, and surface temperatures should be 40° F (4° C) or higher during application. Do not apply sealer when temperatures are expected to fall below 40° F (4° C) within 12 hours.
- A dry surface is suggested for maximum penetration of sealer; however, surfaces to be treated can be slightly damp. Do not apply Sikagard®-200 Enviroseal if standing water is visible on the surface to be treated.
- Crack control, caulking, patching, and expansion joint sealants can be installed before or after the application of the sealer. Allow a minimum of 6–12 hours of curing time for caulking and sealant materials (or until they have skinned over) before applying Sikagard®-200 Enviroseal. Following the application, remove the excess product that might pond on a concave sealant joint.
APPLICATION
- Test a small area of the surface (generally a 5 by 5 ft [1.5 by 1.5 m] section) before starting the general application of any clear, penetrating sealers to ensure desired performance results, aesthetics, and coverage rates. Allow 5–7 days for the product to fully react before evaluating.
- Stir material thoroughly before and during application.
- Low-pressure non-atomizing spray application is recommended.
- On vertical surfaces, apply from the bottom up. Flood surfaces using enough material to get an 8–12" (20–30 cm) material rundown.
- For horizontal surfaces, apply to saturation. If necessary, follow with a squeegee or a broom for even distribution.
CLEANING OF TOOLS
Clean equipment and tools with hot soapy water. Overspray can be cleaned immediately with hot soapy water. Dried residue can be cleaned with a mild citrus-based cleaner or very hot water, then scrubbed with a soft-bristle brush.