Sika® Level-125
Sika® Level-125 is a one-part, polymer-modified, pumpable, self-leveling underlayment for the leveling and smoothing of interior floors prior to the application of the final floor finish. Typical application thickness is 1/8” up to 2” (3.18 mm up to 50.80 mm).
- Easy installations
- Reduced shrinkage
- Levels new and renovates old floors
- Good mechnical strengths
- Fast hardening and good drying
- Suitable for use with radiant heating systems
Usage
- Can be applied manually or by pump to level floors
- Leveling of both large and small surfaces
- Typical uses are in commercial, residential and domestic properties, etc.
- Providing a suitable substrate for ceramic, stone or vitrified clay tiles, carpets, resilient and wood flooring
- Compatible with the Sika® adhesives used to lay these types of floor finishes
Advantages
- Easy installations
- Reduced shrinkage
- Levels new and renovates old floors
- Good mechnical strengths
- Fast hardening and good drying
- Suitable for use with radiant heating systems
Packaging
50 lbs. (22.68 kg) bag
Color
Gray powder
Product Details
ENVIRONMENTAL INFORMATION
LEED v4.1 & LEED v5 California Department of Public Health (CDPH) Standard Method v1.2
Chemical Base
Cement-based, polymer-modified binder system and fillers
Shelf Life
12 months from the date of production if stored properly
Storage Conditions
The product must be stored in original, unopened and undamaged sealed packaging in dry conditions and protected from direct sunlight and moisture at temperatures between 41°F and 86°F (5°C and 30°C). If damp, discard.
Density
~135 lbs/cu.ft (~2,162 kg/m3) at 73°F (23°C) (fresh mortar)
Compressive Strength
| 1 day | ~1,250 psi (~8.62 MPa) |
| 7 days | ~2,500 psi (~17.24 MPa) |
| 28 days | ~4,000 psi (~27.58 MPa) |
Flexural Strength
| ~1,150 psi (~7.93 MPa) (28 days) | (ASTM C293) |
Tensile Adhesion Strength
| ≥ 217 psi (≥ 1.50 MPa) or substrate failure | (ASTM C1583) |
Application
Mixing Ratio
4 qts. (3.79 L) of clean water per bag
Layer Thickness
| Min. | Max. | |
| Neat | 1/8” (3.18 mm) | 2” (50.80 mm) |
| Extended (with aggregates)* | 1/4” (6.35 mm) | 3” (76.20 mm) |
*See application section for more detail
Product Temperature
65°F to 75°F (18°C to 24°C)
Ambient Air Temperature
41°F to 86°F (5°C to 30°C)
Relative Air Humidity
< 75% RH
Dew Point
Beware of condensation!
The substrate and uncured product applied on the floor, must be at least 5°F (3°C) above measured dew point to reduce the risk of condensation, blooming or cement laitance forming on the surface of the applied product.
Substrate Temperature
41°F to 86°F (5°C to 30°C)
Pot Life
20–25 minutes at 73°F (23°C) and 50% RH
Waiting / Recoat Times
Walk-on time: 2–3 hours
Suitable for overcoating with:
| Non-moisture sensitive floor covering | 2–3 hours |
| Moisture sensitive floor covering | 2–3 days up to 3/8” (9.53 mm)* |
*Mat test (ASTM D4263) above 3/8” (9.53 mm)
The actual times will be affected by changing substrate and ambient conditions, particularly the temperature and relative humidity, plus the thickness of the material applied. When overcoating Sika® Level-125 always ensure the moisture content has achieved the required value for the subsequent floor finish adhesive / product being used, as the necessary waiting time will vary (with the application thickness and ambient humidity). Also please refer to the floor finish / adhesive PDS.
Coverage
~22 sq.ft. (~2.04 m2) per bag at 1/4” (6.35 mm) depth
This is an estimated coverage and additional material may be required based on substrate porosity/profile, material wastage or any other variations. Apply material to a test area to calculate the exact coverage for the specific substrate conditions.
APPLICATION INSTRUCTIONS
SURFACE QUALITY
The substrate must be sound and of sufficient compressive strength (minimum 2,900 psi (20 MPa)) with a minimum pull-off strength of 200 psi (1.38 MPa).
Substrate must be clean, dry, stable, homogeneous and even, free of all contaminants such as oil, grease, dust and loose or friable particles. Paint, wax, curing and sealing compounds, laitance and other poorly adhering contents that will interfere with the penetration of primer and adhesion of Sika® Level-125 must be mechanically removed.
Note: Before overall installation begins, Sika recommends the application of several small test patches to determine underlayment application requirements and acceptability of final product performance.
MIXING
- Pour 4 qts. (3.79 L) of clean water (approx. 68°F (20°C)) into a suitably sized and clean mixing container, using a calibrated measuring jug or similar, to ensure strict control of the water content (do not over-water). If available water is not at this temperature, then consideration should be given to cooling/heating the water.
- Add Sika® Level-125 to the water, while slowly mixing, adding the complete contents of the bag.
- Mix with a high-speed drill (> 650 rpm) and an egg beater style mixing paddle to blend water and powder for ~3 minutes, until a lump-free and uniform mix has been produced.
- Do not overmix or allow the paddle to rise above the level of material as this will introduce and entrap air into the mix, potentially shortening the working life or causing pin-holes in the underlayment.
- Let the mixed material stand until the majority of air bubbles have dispersed.
- Do not mix more material than can be used within the stated pot life, taking into consideration ambient temperatures and humidity levels.
CLEANING OF TOOLS
Clean all tools and application equipment with water immediately after use. Hardened/cured material can only be removed mechanically.
FAQ
No, they are not. For standard-size tile < 15”, the substrate flatness tolerance is no more than ¼” variance in 10”. For tile > 15”, the substrate flatness tolerance is no more than 1/8” variance in 10’. This applies to any substrate whether it is a wall, floor, ceiling etc.
No. Thinset is an adhesive, not a patching or leveling compound. Thinsets are
designed to be a certain thickness and when that thickness is greater than what the thinset can handle, shrinking will occur. Use a product that is designed for patching or leveling.
Almost all self-leveling underlayments require a primer. A primer helps with drying, flowability and bonding. Check with the manufacturer to see if the selected SLU needs a primer. For SikaLevel® SLUs, a primer is required for each pour.
Some old “cutback” black residues may contain asbestos. If the residue has asbestos, a professional will need to remove it. If the black residue does not contain asbestos, it may be removed by mechanical means such as sand blasting or grinding. Some products can encapsulate the black residue, preventing mechanical removal. Check Technical Services to find the correct products.
In most cases, flat is better than level. For example, an exterior deck needs to be flat and not level. Building codes require the deck to be pitched away from the building, which would make the deck not level. But, to install tile the deck must be flat. So, it all depends on the application.
When a flooring substrate does not meet industry flatness tolerances or when a substrate needs to be raised/lifted. Every self-leveling underlayment has a thickness threshold it can be used for. Speak with a SikaTile® Technical Representative for assistance.
No, they are not. For standard-size tile < 15”, the substrate flatness tolerance is no more than ¼” variance in 10”. For tile > 15”, the substrate flatness tolerance is no more than 1/8” variance in 10’. This applies to any substrate whether it is a wall, floor, ceiling etc.
No. Thinset is an adhesive, not a patching or leveling compound. Thinsets are
designed to be a certain thickness and when that thickness is greater than what the thinset can handle, shrinking will occur. Use a product that is designed for patching or leveling.
Almost all self-leveling underlayments require a primer. A primer helps with drying, flowability and bonding. Check with the manufacturer to see if the selected SLU needs a primer. For SikaLevel® SLUs, a primer is required for each pour.
Some old “cutback” black residues may contain asbestos. If the residue has asbestos, a professional will need to remove it. If the black residue does not contain asbestos, it may be removed by mechanical means such as sand blasting or grinding. Some products can encapsulate the black residue, preventing mechanical removal. Check Technical Services to find the correct products.
In most cases, flat is better than level. For example, an exterior deck needs to be flat and not level. Building codes require the deck to be pitched away from the building, which would make the deck not level. But, to install tile the deck must be flat. So, it all depends on the application.