Use Sikalastic-501 Primer when applying directly over mineral cap-sheets, mod-bit or other asphalt type surfaces for "bleed-blocking" capability. Apply Sikalastic-501 Primer at a rate of 12 -16 mils (0.75 -1.0 gal per 100 SF) depending on substrate roughness.
Prior to coating any surface, be sure the coating will adhere by performing an adhesion test (ASTM D-903). Sikalastic®-515 FG US may be applied by brush, roller, or spatula. Do not apply when temperatures are below 50 °F (10 °C) or when precipitation is in the forecast within 48 hours. In areas where the roof is subject to foot traffic, it is recommended to apply walkway pads for added protection and slip resistance. Apply Primer to the substrate according to the application instruction from the Product Data Sheet, and allow to dry.
Apply/flash Sikalastic®-515 FG US with or without Sika® Flexitape Heavy according to project specifications on the transitions of round projections, machine legs, sign posts, guide wire straps, inside and outside corners, gutters, parapet walls, penetrations and similar areas. Repair any damaged metal and caulk and seal watertight all screws, seams, transitions, terminations, penetrations, skylights, joints, pipes, voids, protrusions and any areas where water could enter through the roof. On metal roofs with standing seams, apply Sikalastic®-515 FG US sealing them completely. Make certain that all walking pads are appropriately and adequately secured. Use Sikalastic®-515 FG US to caulk all edges of walking pads.
Higher humidity and/or colder temperatures will slow the drying time of Sikalastic®-515 FG US. In colder and/or more humid conditions, apply Sikalastic®-515 FG US at thinner application rates for faster drying times (this will also increase the number of required coats).