Sikalastic®-646 Lo-VOC
Sikalastic®-646 Lo-VOC is a cold liquid applied, highly elastic, aliphatic, single component, low odor, Lo-VOC moisture-triggered polyurethane resin designed for easy application as part of Sikalastic® RoofCoat roofing systems.
- Sikalastic Polyurethane technology has an over 30 year track record
- Moisture triggered chemistry that is rapidly weatherproof after application
- Resistant to ponding water
- Single component - no mixing and ready to use
- Lo-VOC, low odor
- Highly elastic and crack bridging
- Seamless and fully adhered
- Vapor permeable
- UV resistant and non-yellowing
Product Details
Chemical Base
Single component, moisture triggered, aliphatic polyurethane
Shelf Life
15 months
Storage Conditions
Store dry between 35 °F and 77 °F (2–25 °C). Condition material to 50–77 °F (10–25 °C) before using for ease of application.
Density
11.9 lb./gal. (1.4 kg/cm3)
Volatile organic compound (VOC) content
| 38 g/l | ASTM D-2369-81 |
Solid content by volume
| 89 % | ASTM D-2697 |
System Structure
| Layer | RoofCoat 15** | RoofCoat 20** | |
| Primer | See Priming Guide | See Priming Guide | |
| Base Coat | 45 mils wet (~2.75 gal/100 SF) | 45 mils wet (~2.75 gal/100 SF) | |
| Reinforcement | Reemat Premium | Reemat Premium | |
| Top Coat | 20 mils wet (1.25 gal/100 SF) | 30 mils wet (2.0 gal/100 SF) | |
| Total Dry Film | ~58 mils dry | ~67 mils dry |
** All Roofing is Fully Reinforced
-----------------------------------------------------------------------------------------------
Localized Reinforcement: Prior to applying the specified coating system, install Sika® Joint Tape SA or use Sika® Flexitape Heavy embedded in 25-35 wet mils of Sikalastic 646 Lo-VOC, centered over all lap seams, cracks, joints, and transitions of dissimilar marterial.
Note: Coverage rates provided are optimal and are not guaranteed - coverage rates will vary depending on temperature, surface roughness, porosity, aggregate selection, embedment, and application technique.
Resistance to Static Puncture
| 55 lb/f | ASTM D5602 |
Tensile Strength
| 700 PSI | ASTM D412 |
Tear Strength
| 70 lbf/in | ASTM D624 |
Chemical Resistance
Most common roofing contaminants, oils, grease, dilute acids and bases.
Solar Reflectance
| 0.88 | ASTM C-1549 |
Solar Reflectance Index
| 108 | ASTM E-1980 |
Service Temperature
-22 – 176 °F (-30 – 80 °C) intermittent
Application
Ambient Air Temperature
41 - 95 °F (5 - 35 °C)
Relative Air Humidity
80 % R.H. max.
Dew Point
Beware of condensation. The substrate and uncured coating must be ≥ 5 °F (3 °C) above dew point.
Substrate Temperature
41 - 140°F (5 - 60°C)
Substrate Moisture Content
≤ 4 % moisture content as measured with a Tramex Moisture Meter. No rising moisture according to ASTM (Polyethylene-sheet).
If moisture content is above 4 %, use Sikalastic-GDC Primer.
Pot Life
In opened containers, the material will form a film after 1–2 hours approx. at 75 °F (24°C) and 50 % R.H.
Waiting / Recoat Times
| Ambient Conditions | Minimum Waiting Time Overcoating |
| +40 °F / 50 % r.h. | 18 hours |
| +50 °F / 50 % r.h. | 8 hours |
| +70 °F / 50 % r.h. | 6 hours |
*After 7 days the surface must be cleaned and primed with Sika® Reactivation Primer or Sika® Concrete Primer Lo-VOC before continuing.
Note: Times are approximate and will be affected by changing ambient conditions particularly temperature and relative humidity.
Test Results
| Ambient Conditions | Rain Resistant | Touch Dry | Full Cure |
| +40 °F / 50 % r.h. | 1 hour | 12 hours | 24 hours |
| +50 °F / 50 % r.h. | 1 hour | 6 hours | 18–24 hours |
| +70 °F / 50 % r.h. | 1 hour | 4 hours | 12–18 hours |
Note: Times are approximate and will be affected by changing ambient conditions particularly temperature and relative humidity.
APPLICATION INSTRUCTIONS
Substrate Pre-Treatment
Refer to Priming Guide to select primer for properly evaluated and prepared substrate. Refer to separate primer Product Data Sheet for application methods, coverage rates, cure times and recoat windows. Always allow primer to cure thoroughly before applying detail or base resin layer.
Sikalastic® RoofPro-646 Lo-VOC Priming Guide
Substrates and Primer Options
Concrete *1
Sikalastic® Concrete Primer Lo-VOC
Sikalastic® DTE Primer
Sikalastic® GDC Primer
Sikalastic® EP Primer/Sealer
Sikalastic® EP Primer Rapid
Lightweight Structural Concrete *1
Sikalastic® Concrete Primer Lo-VOC
Sikalastic® DTE Primer
Sikalastic® GDC Primer
Sikalastic® EP Primer/Sealer
Sikalastic® EP Primer Rapid
Cement, Gypsum Based Roof Boards
Sikalastic® Concrete Primer Lo-VOC
Sikalastic® EP Primer/Sealer
Sikalastic® EP Primer Rapid
Brick, Stone *3
Sikalastic® Concrete Primer Lo-VOC
Sikalastic® EP Primer/Sealer
Sikalastic® EP Primer Rapid
Bituminous Substrate
Asphalt, Bituminous Felts, Bituminous
Coatings, Granulated or Smooth
SBS & Aged APP Cap Sheets *2,3
Sikalastic® EP Primer/Sealer
Sikalastic® EP Primer Rapid
Single Ply PVC Membranes *3
Sarnafil, Sikaplan *3
Sikalastic® EP Primer/Sealer
Hypalon *3
Sika® Bonding Primer
TPO, EPDM *3
Sikalastic® EPDM / TPO Primer Lo-VOC
Roof Tiles (unglazed) *3,4
Sikalastic® EP Primer/Sealer
Sikalastic® EP Primer Rapid
Fiberglass *3
Sikalastic® EP Primer/Sealer
Sikalastic® EP Primer Rapid
Polyurethane Foam - Sprayed or Slab Stock
Sikalastic® EP Primer/Sealer
Sikalastic® EP Primer Rapid
Metal *3
Aluminium, Galvanized, Cast Iron,
Copper, Lead, Brass, Stainless Steel,
Steel, Zinc
Sikalastic® EP Primer/Sealer
Sikalastic® EP Primer Rapid
Pre-Coated Metal *3
Paints & Coatings *3
Aluminized Solar Reflective Coatings *3
Sikalastic® EP Primer/Sealer
Sikalastic® EP Primer Rapid
Wood - Timber & Plywood *5
Sikalastic® EP Primer/Sealer
Sikalastic® EP Primer Rapid
* Consult Sika.
1 New cementitious substrates must be Portland base and be cured min. 28 days.
2 The presence of volatile bitumen may cause discoloration of Sikalastic® if not properly primed.
3 Surface evaluation and field adhesion testing.
4 Glazed tile consult Sika.
5 Pressure treated lumber consult Sika.
SUBSTRATE PREPARATION
Substrate Evaluation and Preparation
- All substrate surfaces shall be clean, dry, and sound. Acceptable substrates include: sound concrete, metals, wood, modified bitumen, mineralized felt, EPDM, Hypalon, TPO, sprayed polyurethane foam, brick and stone, and existing liquid applied membranes.
- Where coating will be applied directly to substrate surface, provide local reinforcement of lap seams, cracks, joints, and transitions of dissimilar materials, using either Sika Joint Tape SA or Sika Flexitape Heavy embeded in 30-35 mils resin.
Concrete and Cementitious Substrates
Cementitious or mineral based substrates must be prepared mechanically using abrasive blast cleaning or scarifying equipment to remove cement laitance and to achieve an open textured surface (CSP 2-4 per ICRI guidelines). Loose friable material and weak concrete must be completely removed and surface defects such as voids must be fully exposed.
Repairs to the substrate, filling of joints, voids, and surface leveling must be carried out. Consult Sika for product recommendations based on project requirements. High spots must be removed by grinding or similar method. Outgassing is a naturally occurring phenomenon of concrete that can produce pinholes in liquid-applied materials. The concrete must be carefully assessed for moisture content, air entrapment, and surface finish prior to any roofing work. Particular requirements for priming must also be considered. Installing the primer and membrane either when the concrete temperature is falling or stable can reduce outgassing. It is beneficial, to apply the primer and embedment coat in the late afternoon or evening.
Gypsum and Cement-Based Sheathing
Sheathing boards shall be clean, dry, and dust-free, and shall be properly secured to the structure. Loose, damaged, or contaminated boards shall be removed and replaced.
Brick and Stone
Mortar joints must be sound and preferably flush pointed. Power wash and use biodegradable non-sudsing detergent with clean water rinse as required.
Asphalt
Asphalt contains volatiles which can cause bleeding and slight non-detrimental staining. The asphalt must be carefully assessed for moisture and/or air entrapment, grade, and surface finish. Power wash and use biodegradable non-sudsing detergent with clean water rinse as required. All major cracks should be sealed to allow continuity of the Sikalastic® RoofCoat system.
Bituminous Felt
Ensure that bituminous felt is firmly adhered or mechanically fixed to the substrate. Bituminous felt shall not contain badly degraded areas.
Bituminous Coatings
Remove any loose or degraded coatings. Bituminous coatings shall not have sticky or mobile surfaces. Volatile mastic coatings, or old coal tar coatings are not acceptible. Power wash and use biodegradeable non-sudsing detergent with clean water rinse as required. Treat blisters by star cutting and removing any underlying water. Allow to dry and re-adhere using suitable adhesive.
Metals
Metals must be in sound condition. Ferrous metals should be thoroughly cleaned by grinding or blast cleaning prior to priming (SSPC-SP3 to SP11 near-white metal). Non-ferrous metals are prepared by removing any deposits of dust and oxidation and abrading to bright metal. Wire brushing can be used for galvanized or soft metal such as lead and copper. The surface must be clean and free from grease which, if present, must be removed with a solvent wipe or wash with detergent, rinse and dry. Stainless Steel must be mechanically abraded or ground to create an appropriate anchor profile.
Paints and Coatings
Remove any loose or degraded coatings. Ensure the surface is clean and free from grease. Ensure the existing material is sound and firmly adhered.
Existing Sikalastic® Systems
The existing Sikalastic® System is soundly adhered to the substrate. Clean the membrane using a pressure washer at approximately 140bar (2000 psi) and biodegradable non-sudsing detergent with a clean water rinse. Allow the membrane surface to dry.
Wooden Substrates
Timber and timber based roof decks require additional reinforcement such as the installation of plywood, approved insulation, or cover board. Small timber protrusions and suitable decks may be treated directly, provided that the timber is of exterior quality, e.g. plywood. Fill joints flush with Sikaflex® sealant.
Sikaplan®/Sarnafil® Membranes
Clean the membrane using a pressure washer at approximately 140bar (2000 psi) and biodegradable non-sudsing detergent with a clean water rinse. Allow the membrane surface to dry.
APPLICATION
Detailing
Non-structural Cracks Up To 1/16''
Detail application not necessary. Apply base coat per below.
Non-structural Cracks Between 1/16'' and 1/4''
Rout and seal with Sikaflex®-11 FC sealant. Allow Sikaflex®-11 FC to skin over. Apply 30-35 mil resin layer embedding 3'' Sika Flexitape Heavy centered over the crack. Alternatively, allow Sikaflex®-11 FC to cure then apply Sika® Joint Tape SA centered over the crack. Apply base coat per instruction.
Metal Seams, Plywood, Board Joints
Apply 30-35 mil resin layer embedding 3 or 6'' Sika® Flexitape Heavy centered over seams. Alternatively, Sika® Joint Tape SA can be applied centered over seams. Apply base coat per instruction.
Transitions Between Dissimilar Materials
Apply appropriate primer for each substrate as indicated in the primer guide. Apply 30-35 mil of Sikalastic 646 Lo-VOC embedding 6" Sika® Flexitape Heavy centered over the edge. Apply base coat per instruction.
Vertical to Horizontal Transitions
Apply appropriate primer for each substrate as indicated in the primer guide. Apply a 1/2" cant bead of Sikaflex®-11 FC at the transition from horizontal to vertical. Allow Sikaflex®-11 FC to skin over. Apply 30-35 mil resin layer embedding 6'' Sika® Flexitape Heavy centered over the cant bead. Alternatively, allow Sikaflex®-11 FC to cure then apply Sika® Joint Tape SA centered over the cant bead. Apply base coat per instruction.
Lap Seams
Prior to applying the roof coating cover lap seams with 3" or 6" Sika Joint Tape SA or Sika Flexitape Heavy embeded with 30-35 mils of resin. Follow by applying base coat per instruction.
Embedment/Base Resin Layer With Sika® Reemat Reinforcement
Mixing not required. Apply Sikalastic®- 646 Lo-VOC at the coverage rate using a 1/2'' nap phenolic resin core roller. Material can also be squeegee or spray applied, in which case it should be backrolled prior to embedding Sika® Reemat Premium. Place Sika® Reemat Premium in wet base resin layer overlapping seams a minimum of 2'' (place frayed edge over cut edge of roll) and apply wet roller to topside to saturate completely. After approximately 5 minutes the binder will begin to dissolve allowing the fiber strands to conform to irregular surfaces. Do not over work once the fibers have conformed to the substrate. Allow to cure 12 hours at 70 °F and 50 % R.H. or until tack free before top resin layer. Keep clean and dry and apply top resin layer within 7 days. If window is exceeded clean with non-sudsing detergent and clean water rinse, and allow to dry prior to application of Sika® Concrete Primer Lo-VOC or Sika® Reactivation Primer.
Top Resin Layer With Sika® Reemat Premium Reinforcement
Mixing not required. Apply Sikalastic®- 646 Lo-VOC at the coverage rate with a 1/2'' nap phenolic resin core roller. Material can also be squeegee or spray applied, in which case it should also be backrolled. On top of the complete Sikalastic system additional resin layers may be applied with aggregate for slip resistance. Keep clean and dry and apply additional resin layers within 7 days. If window is exceeded clean with non-sudsing detergent and clean water rinse, and allow to dry prior to application of Sika® Concrete Primer Lo-VOC or Sika® Reactivation Primer.
Seed and Back Roll Option
The Seed and Backroll option is primarily intended for use as maintenance traffic roof walkway applications where enhanced slip resistance is required. Apply Sikalastic 646 Lo-VOC resin at 15 mils wet film thickness to the installed, cured RoofCoat system. While the supplemental resin application is still wet seed with kiln-dried, iron-free aggregate. Back roll the surface to encapsulate the aggregate in the Sikalastic 646 Lo-VOC resin.
Full Broadcast and Seal Option
The Full Broadcast and Seal option is intended for use for applications where both enhanced slip resistance and physical protection of the roofing membrane is required. Apply Sikalastic 646 Lo-VOC resin at 15 mils wet film thickness to the installed, cured RoofCoat system. While the supplemental resin application is still wet broadcast to rejection (full broadcast, beach) with kiln-dried, iron-free aggregate. Remove excess aggregate after cure. Seal with an additional 15 mil coat of Sikalastic 646 -VOC.
CLEANING OF TOOLS
Clean all tools and application equipment with appropriate solvent immediately after use. Hardened and/or cured material can only be removed mechanically.