Sika® Ucrete® RG
(formerly Ucrete® RG)
Hygienic, heavy-duty polyurethane render and coving mortar
0.0 (0)
Sika® Ucrete® RG is a heavy-duty polyurethane render and coving mortar. It has very good resistance to aggressive chemicals, heavy abrasion and temperatures up to 248°F (120°C).
- Expert installation by fully trained applicators
- Does not support bacterial or mold growth
- Suitable for application on to 7-day-old concrete and 3-day-old polymer screed
- Very good resistance to a wide range of chemicals
- Very good mechanical resistance
- Impermeable to liquids
- Non-tainting from the end of mixing
- Low VOC emissions
- Thermal expansion properties similar to concrete
Usage
Sika® Ucrete® RG is used as a render and mortar for Sika® Ucrete® flooring systems. Sika® Ucrete® RG is used within wet and dry process areas including the following application areas:- Food and beverage facilities
- Pharmaceutical facilities
- Chemical and processing facilities
- Manufacturing facilities and workshops
- Bunding areas
- Drianage channels
- Tank bases
- Sumps
- Effluent storage pits
- Coving and skirting
- The Product may only be used by experienced professionals.
Advantages
- Expert installation by fully trained applicators
- Does not support bacterial or mold growth
- Suitable for application on to 7-day-old concrete and 3-day-old polymer screed
- Very good resistance to a wide range of chemicals
- Very good mechanical resistance
- Impermeable to liquids
- Non-tainting from the end of mixing
- Low VOC emissions
- Thermal expansion properties similar to concrete
Packaging
Refer to the current price list for available packaging variations.
Color
Cured color | Red, Orange, Yellow, Cream, Grey, Light Grey, Green, Light Green, Green/ Brown, Blue. |
Product Details
APPROVALS / STANDARDS
Food and Beverage Facilities Suitability, Sika® Ucrete®, HACCP, Test Report No. I-PE-769-SA-2-RG-06b
Halal Certification Europe (HCE), Sika® Ucrete®, WHFC, Certificate No. 21453-2/1/1/Y1
Indoor Air Comfort Gold EN 16516, Sika® Ucrete®, eurofins, Certificate No. IACG-321-01-01-2023
Chemical Base
Water-based polyurethane cement hybrid
Shelf Life
Always refer to the best-before date of the individual packaging.
Storage Conditions
The Product must be stored in original, unopened and undamaged sealed packaging in dry conditions at temperatures between 41°F and 86 °F. Always refer to the packaging.
Refer to the current Safety Data Sheet for information on safe handling and storage.
Compressive Strength
Cured 28 days at 73°F | 7542 psi |
Flexural Strength
Cured 28 days at 73°F | 2176 psi |
Tensile Strength
Cured for 28 days at 68°F | 1015 psi |
Tensile Adhesion Strength
> 290 psi (concrete failure) | (ASTM D4541) |
Water permeability
Sika® Ucrete® RG exhibits zero absorption when tested to CP.BM2/67/2.
Chemical Resistance
Laboratory-defined resistance to many individual chemicals. Before proceeding, contact Sika Technical Service for specific information.
Reaction to Fire
Class Bfl-s1 | (EN 13501-1) |
Application
Product Temperature
Maximum | 77°F |
Minimum | 59°F |
Ambient Air Temperature
Maximum | 77°F |
Minimum | 59°F |
Substrate Temperature
Maximum | 77°F |
Minimum | 59°F |
Cure Time
Substrate temperature | Return to traffic |
46°F | < 24 hours |
Note: Times are approximate and will be affected by changing ambient and substrate conditions.
Coverage
Layer | Product | Consumption |
Wearing layer | Sika® Ucrete® RG | 12 ft2/kit for 1/8" 10 ft2/kit for 3/16" |
SUBSTRATE PREPARATION
IMPORTANT
Reduced service life due to incorrect treatment of cracks
The incorrect assessment and treatment of cracks may lead to a reduced service life and reflective cracking.
- For static cracks, ensure the width is suitable for overcoating with Sika® Ucrete® RG.
- For dynamic cracks, ensure the movement is within the movement capacity of Sika® Ucrete® RG.
TREATMENT OF JOINTS AND CRACKS
Construction joints and existing static surface cracks in substrate require pre-treating before full layer application. Use Sikadur® or Sikafloor® resins.
The System can be applied on green or damp concrete with no standing water. Allow for at least 3 days for early concrete shrinkage to occur to prevent shrinkage cracks from appearing on the wearing surface.
Cementitious substrates must be structurally sound and of sufficient compressive strength (minimum 3625 psi, 25 N/mm2) with a minimum tensile strength of 217 psi.
Substrates must be clean, dry and free of contaminants such as dirt, oil, grease, coatings, laitance, surface treatments and loose friable material.
APPLICATION
Application must be undertaken by a fully trained Sika® Ucrete® applicator.