Usage
SikaBond®-T53 is designed for use with the Sika® AcouBond®-System and beaded application of solid wood boards (tongued and grooved), 3-ply engineered wood and chipboard floor systems and subfloors.Advantages
- Excellent adhesion on all cement-based materials, brick, ceramics, glass, metals, and wood
- Fast cure rate
- Waterproof and water immersible after cure
- Good weathering resistance
- Non-corrosive
- Can be painted over with water, oil, and rubber-based paints (Preliminary tests recommended)
- High durability and flexible
- Can be used to fill in gaps
- Off-white in color
Packaging
600 ml foil pack, 20 foil packs per box
Color
Beige
Product Details
Chemical Base
Polyurethane
Shelf Life
SikaBond®-T53 has a shelf life of 12 months from the date of production, if it is stored properly in undamaged, original, sealed packaging, and if the storage conditions are met.
Storage Conditions
SikaBond®-T53 shall be stored in dry conditions, protected from direct sunlight and at temperatures between +5 °C and +25 °C.
Density
1.20 kg/l approx. | (ISO 1183-1) |
Shore A Hardness
40 approx. (after 28 days) | (ISO 868) |
Tensile Strength
1.8 N/mm2 approx. | (ISO 37) |
Shear Strength
1.20 N/mm2 approx., 1 mm adhesive thickness | (ISO 17178) |
Service Temperature
+5 °C to +40 °C
Application
Sag Flow
SikaBond®-T53 maintains stable trowel marks.
SikaBond®-T53 is easily applied using guns or SikaBond® Dispensers.
Ambient Air Temperature
+15 °C to +35 °C
Relative Air Humidity
40% to 70%
Substrate Temperature
During laying and until SikaBond®-T53 has fully cured, the substrate and ambient temperatures shall be between +15 °C and +35 °C without and between +20 °C and +35 °C with underfloor heating
Substrate Moisture Content
Permissible substrate moisture content without underfloor heating:
- 2.5% CM for cement screeds.
- 0.5% CM for anhydrite screeds.
- 3–12% CM for magnetite flooring (depending on the organic content).
Permissible substrate moisture content for use with underfloor heating:
- 1.8% CM for cement screeds.
- 0.3% CM for anhydrite screeds.
- 3–12% CM for magnetite flooring (depending on the organic content).
Note: For all moisture contents, the quality of the substrates and surfaces, always follow the guidelines of the wood flooring manufacturer.
Curing Rate
3.0 mm/24 hours approx. (23 °C / 50% r.h.)
Skin Time / Laying Time
60 minutes approx. (23 °C / 50% r.h.)
Coverage
10.1 oz (300 ml) Cartridge: Yield in Linear feet
Width/Depth | 1/4'' | 3/8'' | 1/2'' |
1/4'' | 24.3 | ||
3/8'' | 16.2 | 10.8 | |
1/2'' | 12.1 | 8.1 | 6.1 |
3/4'' | 8.1 | 5.4 | 4.0 |
1'' | 3.0 | ||
1.25'' | 2.4 | ||
1.5'' | 2.0 |
20 oz (600 ml) Sausage: Yield in Linear feet
Width/Depth | 1/4'' | 3/8'' | 1/2'' |
1/4'' | 48.1 | ||
3/8'' | 32.1 | 21.4 | |
1/2'' | 24.1 | 16.0 | 12.0 |
3/4'' | 16.0 | 10.7 | 8.0 |
1'' | 6.0 | ||
1.25'' | 4.8 | ||
1.5'' | 4.0 |
APPLICATION INSTRUCTIONS
For the application of SikaBond®-T53 all standard construction guidelines apply.
For further information, please refer to the Method Statement "Full Surface Bonding".
SUBSTRATE PREPARATION
- The substrate must be clean, dry, sound and homogeneous, free from oils, grease, dust and loose or friable particles. Paint, cement laitance and other poorly adhering contaminants must be removed.
- Concrete and/or cement screeds must be ground and thoroughly cleaned with an industrial vacuum.
- Anhydrite screeds, including flowable anhydrite screeds must be ground and thoroughly cleaned with an industrial vacuum shortly before bonding with the adhesive starts.
- Broadcast mastic asphalt must be primed with Sika® Primer MR Fast, Sika® Primer MB, or Sika® MB EZ Rapid. For the instructions for use, please refer to the corresponding Product Data Sheet.
- Glazed ceramic and old existing ceramic tiles must be degreased and cleaned with Sika® Aktivator-205, or the tile surfaces must be ground and then thoroughly cleaned with an industrial vacuum.
- Wood and/or gypsum boards (e.g. chipboard, plywood) must be glued and/or screwed to the substructure in order to be fixed to the substrate. For floating dry-floors, contact our Technical Service Department.
- For other substrates contact our Technical Service Department for advice and assistance.
- SikaBond®-T53 can be used without priming on cement based floors, anhydrite floors, chipboards, concrete and ceramic tiles.
- For broadcasted mastic asphalt, cement based floors with excessive moisture content and use over old adhesive residues or on weak substrates use Sika® Primer MB. For detailed instructions contact our Technical Service Department.
CLEANING OF TOOLS
Clean all tools and application equipment immediately after use with Sika® Remover-208 and/or Sika® TopClean T. Once cured, residual material can only be removed mechanically.