Sikalastic®-500
0.0 (0)
Sikalastic®-500 is a versatile, low VOC, ultra high solids, single-component, liquid applied silicone roof coating. It provides superior UV resistance over a variety of roof substrates. The main features of Sikalastic®-500 are its high solids content, rapid cure and superior physical properties. Certified to meet CoolRoofRatingCouncil (CRRC) and EPA guidelines for ENERGY STAR® compliance.
- VOC Compliant: < 50 g/l VOC maximum in California.
- UV resistant: Slows degradation caused by normal weathering, aging, and ultraviolet rays
- Reflective Top Coat: Can reduce cooling costs by reflecting UV rays. The high reflectivity also helps colors maintain their original appearance, whereas other roof coatings tend to fade and sun bleach at faster rates.
- Waterproof with better ponding water resistance.*
- Durability: Infrequent and low maintenance costs.
- High tensile strength and abrasion resistance.
- Excellent adhesion to a variety of roof surfaces.
- Ease of application - fast and simple to install.
- Can be used to reinforce penetrations and terminations ,and make spot repairs.
- Retains its integrity from -80 °F to 250 °F (-62–121 °C)
- Accelerator available to shorten cure time.
- Open window (recoat time) maximum 7 days between the coats.
Usage
The complete system provides tenacious adhesion with an existing roof system to form a monolithic membrane. These existing roofs include but are not limited to modified bitumen/built-up roofs, concrete, EPDM/HYPALON, PVC, TPO, and metal.Advantages
- VOC Compliant: < 50 g/l VOC maximum in California.
- UV resistant: Slows degradation caused by normal weathering, aging, and ultraviolet rays
- Reflective Top Coat: Can reduce cooling costs by reflecting UV rays. The high reflectivity also helps colors maintain their original appearance, whereas other roof coatings tend to fade and sun bleach at faster rates.
- Waterproof with better ponding water resistance.*
- Durability: Infrequent and low maintenance costs.
- High tensile strength and abrasion resistance.
- Excellent adhesion to a variety of roof surfaces.
- Ease of application - fast and simple to install.
- Can be used to reinforce penetrations and terminations ,and make spot repairs.
- Retains its integrity from -80 °F to 250 °F (-62–121 °C)
- Accelerator available to shorten cure time.
- Open window (recoat time) maximum 7 days between the coats.
Packaging
5 gal. (19 L) pail
55 gal. (208 L) drum
Color
White, Tan, Light Gray, Custom Colors available upon request
Product Details
APPROVALS / STANDARDS
- Miami Dade: NOA No.: 17-0824.02
- NSF/ANSI 61 Section 5 - 2016
- CRRC listed, Product ID 0674-0040
- UL 790, File R 39379
Class A for Fluid Applied Coating System on DensDeck® Roofboard with unlimited slope
Class A, B or C for Maintenance and Repair Systems*
*Existing Roof System: — Any Class A, B or C uncoated, insulated or uninsulated, modified bitumen membrane, Type G3 mineral surfaced cap BUR, EPDM, TPO, Hypalon, PVC, TPA, or CPE single ply membrane system, mechanically fastened or fully adhered, to retain existing Classification. (Classification and maximum incline will be the same as that of the Classified Roofing System)
Chemical Base
Moisture cured Silicone
Shelf Life
12 months (unopened container)
Storage Conditions
Keep containers closed and store in a dry, cool place away from heat, sparks, open flame, excessive heat, and moisture. Keep material stored above 65 °F (18 °C). Open containers should be blanketed with dry nitrogen before using.
Solid content by mass
92-96 % | (ASTM D2697) |
Solid content by volume
92-96 % | (ASTM D2697) |
Viscosity
12,500 +/- 2,500 cps. (at 75 °F (24 °C) and 50 % R.H.)
System Structure
Apply Sikalastic®-500 at the below coverage rates for the respective system length.
NOTE: The below coverage rates are the minimum required. Rough, irregular or granulated surfaces may require additional coating to meet minimum dry film mils.
RoofCoat 10 | RoofCoat 15 | RoofCoat 20** | |
Primer | See Primer Chart | See Primer Chart | See Primer Chart |
Sikalastic®-500 | 24 wet mils (1.5 gal/100 SF) | 32 wet mils (2.0 gal/100 SF) | 40 wet mils (2.5 gal/100 SF) |
**2 coats are recommended for a more uniform application
Shore A Hardness
50 +/- 5 | (ASTM D2240) |
Tensile Strength
300 psi | (ASTM D2370) |
Tear Strength
45 lb./in. | (ASTM D624) |
Solar Reflectance
0.88 | (ASTM C1549) |
Thermal Emittance
0.91 | (ASTM C1371) |
Solar Reflectance Index
112 | (ASTM E1980) |
Permeability to Water Vapor
7.9 US Perms | (ASTM E96) |
Application
Ambient Air Temperature
41 °F (5 °C) min. / 95 °F (35 °C) max.
Relative Air Humidity
80 % R.H. max.
Dew Point
Beware of condensation.
The substrate and uncured coating must be ≥ 5 °F (3 °C) above dew point.
Substrate Temperature
41 °F (5 °C) min. / 140°F (60°C) max.
Substrate Moisture Content
≤ 4 % moisture content Test method: Sika®-Tramex meter
No rising moisture according to ASTM (Polyethylene-sheet)
Drying Time
without Accelerator | 4 hours | at 75 °F (24 °C) and 50 % R.H. |
with Accelerator | 2 hours | at 75 °F (24 °C) and 50 % R.H. |
Coverage
1.5 gal./100 sq.ft - 24 mils wft
2.5 gal./ 100 sq.ft- 40 mils wft
SUBSTRATE PREPARATION
- Applicator is responsible for confirming the roof is in sound condition with an acceptable, fully secured substrate, proper slope to drain, and is readily acceptable for a coating restoration system.
- Applicator is responsible for completing a moisture scan of all roof surfaces to receive Sikalastic®-500. Any wet insulation should be removed and replaced. The roof areas where insulation was removed and replaced, repair with a like roof system to the exiting roof system before applying Sikalastic®-500.
- Tighten and/or replace all existing fasteners. Install crickets and complete all needed sheet metal repairs.
- Remove all unnecessary and non-functional equipment and debris from the roof.
- Remove dirt, and foreign material detrimental to adhesion or application of fluid-applied roofing by thoroughly cleaning all roof surfaces with a high pressure (2,000–2500 psi, 13.79–17.24 MPa) wash. Surfaces contaminated with oil, grease, animal fats, etc. must be removed using tri-sodium phosphate and water, or other solutions as required by job conditions and as permitted by local, state, and federal regulations. Remove all cleaning solutions with plenty of fresh water and allow to dry.
- Membranes with seam and flashing failures must be repaired using traditional and professional corrective measures and then detailed.
- Seal to watertight around projections, machine legs, sign posts, guide wire straps, inside and outside corners, cant strips, gutters, parapet walls, caps, and seal watertight all screws, seams, skylights, joints, pipes, voids, protrusions and any areas where water could enter through the roof.
- Clean and seal all areas around drains to watertight.
- Allow roof and other prepared surfaces to dry completely before proceeding with field priming and/or coating application.
- Note: Thickness values of cured films are averages and can vary due to surface finish. Rough, irregular or granulated surfaces may require additional coating to meet minimum dry film mils.
- Prior to coating any surface, be sure the coating will adhere by performing an adhesion test (ASTM D-903).
- Prime all surfaces with the appropriate primer listed above according to the application instructions from the Primers' Product Data Sheet, and allow to dry before applying details or field coating.
- Always check the weather prior to application. Depending on the ambient, and substrate temperatures, relative humidity, and dew point take extra time and caution when applying the system within 2 to 6 hours of precipitation and/or when raw or freezing temperatures are experienced or anticipated. Do not apply over wet insulation or related materials.
- Sikalastic®-500 shall extend a minimum of 3'' (76.2 mm) beyond the edges of the repair, feathered onto the substrate.
MIXING
Mix 55 gal. (208 L) drums and 5 gal. (19 L) pails with a variable speed drill utilizing a jiffy mixer to suspend any settled pigments until a uniform color and consistency is achieved. Mixing time will vary based on temperature and atmospheric conditions. Usually 3 minutes.
APPLICATION
Prior to coating any surface, be sure the coating will adhere by performing an adhesion test (ASTM D-903). Coating may be applied by brush, roller, or airless spray equipment. Do not apply when temperatures are below 41 °F (5 °C) or when precipitation is in the forecast within 24 hours. In areas where the roof is subject to foot traffic, it is recommended to apply walkway pads for added protection and slip resistance. Apply appropriate primer to the substrate according to the application instruction from the Primer PDS, and allow to dry.
Always start with details using Sika® Flexitape Heavy embedded in Sikalastic®-500 or Sikalastic®-500 Flash, or Sika® Joint Tape SA, including: round projections, machine legs, sign posts, guide wire straps, inside and outside, corners, gutters, parapet walls, penetrations and similar areas. Repair any damaged metal and caulk and seal watertight all screws, seams, transitions, terminations, penetrations, skylights, joints, pipes, voids, protrusions and any areas where water could enter through the roof. On metal roofs with standing seams, apply Sika® Joint Tape SA, or Sika Flexitape Heavy embedded in Sikalastic®-500 Flash, sealing them completely. Metal roof projects requiring a warranty should be pre-inspected by a Sika Representative for metal seam detailing. Make certain that all walking pads are appropriately and adequately secured. Use Sikalastic®-500 Flash to caulk all edges of walking pads.
Apply Sikalastic®-500 at the below coverage rates for the respective system length. NOTE: The below coverage rates are the minimum required. Rough, irregular or granulated surfaces may require additional coating to meet minimum dry film mils
System Length | Gal/Square | Dry Mils |
10 years | 1.5 | 23 |
15 years | 2.0 | 31 |
20 years | 2.5 | 38 |
Roof coatings should be properly maintained following industry standards of care and maintenance including annual inspections by qualified roofing contractors. All required maintenance or repairs should be undertaken immediately.