Sikaplan® Universal-60 Feltback EnergySmart
60 mil thick PVC thermoplastic membrane with felt backing
Sikaplan® Universal-60 Feltback EnergySmart Roof Membrane is a PVC thermoplastic membrane produced with a polyester scrim reinforcement and a 9 oz. recycled felt backing.
- Highly reflective
- Excellent tear strength resistance
- Factory applied lacquer coating to reduce dirt pick up
- Hot-air welded seams for long-term performance
Usage
Used in adhered and mechanically attached applications to approved substrates. AREAS OF APPLICATION- Adhered roof systems
- In-seam disc systems
- In-seam batten, double-weld systems
- RhinoBond® systems
- New construction and reroofing
Advantages
- Highly reflective
- Excellent tear strength resistance
- Factory applied lacquer coating to reduce dirt pick up
- Hot-air welded seams for long-term performance
Packaging
60 mil (1.5 mm) Membrane 9oz. Feltback:
10 ft x 100 ft (3 m x 30 m) feltback roll, 388 lbs (176 kg) per roll, 9 rolls per pallet
Colour
- Top: White, Reflective Gray, and Tan
- Bottom: Gray
Product Details
APPROVALS / STANDARDS
- FM Global
- Underwriters Laboratories
- Underwriters Laboratories of Canada
- ICC Code Compliance – ESR 1157
- Miami‐Dade County
- Florida Building Code
- California Title 24
- LEED/Green Globes
Chemical Base
Thermoplastic PVC membrane containing ultraviolet light stabilizers, flame retardant and polyester scrim reinforcement with a unique lacquer coating on the top surface.
Recycled Content
9% Pre‐consumer, 1% Post‐consumer
Reinforcing Material
Polyester
Shelf Life
N/A
Storage Conditions
Store rolls on pallets and fully protected from the weather with clean canvas tarpaulins. Unvented polyethylene tarpaulins are not accepted due to the accumulation of moisture beneath the tarpaulin in certain weather conditions that may affect the ease of membrane weldability.
Overall Thickness
60 mil (1.5 mm), nominal 45 mil | (ASTM D-751) (ASTM Type III D-4434 Spec. Requirement) |
Thickness Above Scrim
24 mil 16 mil | (ASTM D-7635) (ASTM Type III D-4434 Spec. Requirement) |
Felt Weight
9 oz/yd2
Resistance to Static Puncture
Pass 33 lbf (15 kg) | (ASTM D-5602) (ASTM Type III D-4434 Spec. Requirement) |
Resistance to Dynamic Puncture
Pass 14.7 ft-lbf (20 J) | (ASTM D-5635) (ASTM Type III D-4434 Spec. Requirement) |
Tensile Strength
303 lbf (1348 N) 200 lbf (890 N) | (ASTM D-751) (ASTM Type III D-4434 Spec. Requirement) |
Linear Dimensional Change
0.24% 0.5% | (ASTM D-1204) (ASTM Type III D-4434 Spec. Requirement) |
Tear Strength
45 lbf (200 N) 45 lbf (200 N) | (ASTM D-751) (ASTM Type III D-4434 Spec. Requirement) |
Seam Strength
Pass 75% of original1 | (ASTM D-751) (ASTM Type III D-4434 Spec. Requirement) |
1 Failure occurs through membrane rupture not seam failure.
Retention of Properties after Heat Ageing
Breaking Strength, % of original: Pass | (ASTM D-751) |
Elongation, % of original: Pass | (ASTM D-751) |
Breaking Strength, % of original: 90 | (ASTM Type III D-4434 Spec. Requirement) |
Elongation, % of original: 90 | (ASTM Type III D-4434 Spec. Requirement) |
UV Exposure
Pass 5,000 hours | (ASTM G-154) (ASTM Type III D-4434 Spec. Requirement) |
Cracking (7x magnification) | None |
Crazing (7x magnification) | None |
Weight Change after Immersion in Water
2.5% | (ASTM D-570) |
±3.0% | (ASTM Type III D-4434 Spec. Requirement) |
Solar Reflectance
EnergySmart Colors | Initial Solar Reflectance | 3-Year Solar Reflectance1 |
EnergySmart White | 0.86 | 0.722 |
EnergySmart Reflective Gray | 0.73 | 0.66 |
EnergySmart Tan | 0.72 | 0.65 |
1 Solar Reflectance testing according to ASTM C-1549
2 Solar Reflectance testing according to ASTM D-7897
Thermal Emittance
EnergySmart Colors | Initial Thermal Emittance | 3-Year Thermal Emittance1 |
EnergySmart White | 0.91 | 0.912 |
EnergySmart Reflective Gray | 0.89 | 0.88 |
EnergySmart Tan | 0.89 | 0.88 |
1 Thermal Emittance testing according to ASTM C-1371, Slide Method
2 Solar Reflectance testing according to ASTM D-7897
Solar Reflectance Index
EnergySmart Colors | Initial Solar Reflectance Index | 3-Year Solar Reflectance Index1 |
EnergySmart White | 108 | 892 |
EnergySmart Reflective Gray | 90 | 80 |
EnergySmart Tan | 88 | 78 |
1 Solar Reflectance Index calculated according to ASTM E-1980
2 Solar Reflectance Index calculated according to ASTM D-7897
Low Temperature Bend
Pass Pass ‐40°F (‐40°C) | (ASTM D-2136) (ASTM Type III D-4434 Spec. Requirement) |
Elongation at break
20 & 20% MD & CMD1 15 & 15% MD & CMD1 | (ASTM D-751) (ASTM Type III D-4434 Spec. Requirement) |
1 MD = Machine Direction, CMD = Cross Machine Direction.
Application
APPLICATION
Sikaplan® Universal-60 Feltback EnergySmart is installed on acceptable substrates and fastened to the roof deck using the approved attachment method. In adhered applications, the membrane is unrolled into approved Sikaplan or Sarnacol adhesive in accordance with Sika's technical requirements and then pressed into place with a minimum 75 lb (34 kg) steel roller. The membrane is heat‐welded together by trained mechanics using hot‐air welding equipment.