Sikalastic® Rapid 724
Sikalastic® Rapid 724 is a two‐component polymethyl methacrylate‐based (PMMA) liquid resin used in flashing applications. Sikalastic® Rapid 724 is used with Sikalastic® Rapid Fleece and cures to form a monolithic reinforced flashing membrane.
- Compatible with Sika membranes
- High performance liquid flashing solution for complex details
- Fleece reinforced flashing system for strength and durability
Usage
Liquid resin used for flashing roofing details AREAS OF APPLICATION- Details that are difficult to flash with a sheet
- Angle Iron
- H-Beam / I-Beam
- Close Multiple Conduits
- Exposed Flashings
- Membrane Termination
Advantages
- Compatible with Sika membranes
- High performance liquid flashing solution for complex details
- Fleece reinforced flashing system for strength and durability
Packaging
2.5 gallon (9.7 L) pails, 26.5 lbs (12 kg) per pail, 60 pails per pallet
Color
White and Gray
Product Details
Chemical Base
Two-component polymethyl methacrylate (PMMA) liquid resin
Shelf Life
Up to 12 months in the original unopened pail when properly stored, sealed and unmixed.
Storage Conditions
Store in a tightly closed container in a cool, dry, ventilated area away from heat and oxidizing agent. Do not store in direct sunlight or in temperatures below 55°F (13°C) or above 80°F (27°C). Keep away from open fire, flame or any ignition source.
Volatile organic compound (VOC) content
5 g/L (Sikalastic® Rapid 724 + Sikalastic Rapid Catalyst PMMA combined)
Testing
| 70 (Shore A Hardness) | (ASTM D-2240) |
Resistance to Static Puncture
| 56 lbf (249 N) | (ASTM D-5602) |
Tensile Strength
| 70 lbf (12.3 kN/m) peal load @ 73°F (23°C) | (ASTM D-5147) |
Dimensional Stability
| 0.1 % | (ASTM D-5147) |
Tear Strength
| 80 lbf (356 N) | (ASTM D-1475) |
Water Absorption
| 0.8% | (ASTM D-570) |
Low Temperature Bend
| 33°F (-36.1°C) | (ASTM D-7264) |
Elongation at break
| 55% Elongation @ peak load | (ASTM D-5147) |
Application
Mixing Ratio
| Temperature Range | Catalyst required (per liter of resin) |
| 50°F to 68°F (10°C to 20°C) | 5 tablespoons (50 g) |
| 68°F to 95°F (20°C to 35°C) | 2.5 tablespoons (25 g) |
Product Temperature
50°F to 86°F (10°C to 30°C)
Ambient Air Temperature
50°F to 95°F (10°C to 35°C)
Substrate Temperature
50°F to 122°F (10°C to 50°C)
Pot Life
15 to 20 minutes
All working and cure times are approximate and may vary upon wind, humidity and ambient/surface temperatures
Cure Time
3 to 6 hours @ 75°F (24°C)
All working and cure times are approximate and may vary upon wind, humidity and ambient/surface temperatures
Waiting / Recoat Times
60 to 90 minutes
All working and cure times are approximate and may vary upon wind, humidity and ambient/surface temperatures
Coverage
APPROXIMATE COVERAGE RATES
| SUBSTRATE PROFILE | BASE COAT | TOP COAT | TOTAL THICKNESS |
| SMOOTH | 63 mils (1.6mm) | 35 mils (0.9 mm) | 98 mils (2.5 mm) |
| TYPICAL | 71 mils (1.8mm) | 35 mils (0.9 mm) | 106 mils (2.7 mm) |
| SBS GRANULATED SHEET | 87 mils (2.2 mm) | 35 mils (0.9 mm) | 122 mils (3.1 mm) |
| ROUGH | 105 mils (2.7 mm) | 35 mils (0.9 mm) | 140 mils (3.6 mm) |
All values are nominal. Coverage rates may vary depending on substrate conditions and the application technique. Wet and dry thicknesses are always equivalent.
SUBSTRATE PREPARATION
- All surfaces should be clean, dry, free of dirt, dust, debris, loose particles, loose paint, rust and other contaminants.
- If the membrane is old or extremely soiled, use Sika approved cleaner to restore the membrane to a `like new’ condition before applying Sikalastic® Rapid 724.
- Clean and prepare metal surfaces to near white metal in accordance with SSPC-SP3 (power tool clean). If power tools are not available, use abrasive paper with a grain size of 20 to 40 to remove all loose particles including paint flakes and rust.
- Grind concrete and masonry surfaces with diamond cup wheel to remove laitance and contaminants.
- Lightly sand rigid PVC and plastic surfaces. Extend surface preparation a minimum of 1/8" (3 mm) beyond the termination of the flashing.
- Wipe metal surfaces with Sika approved cleaner and allow to dry.
- For repairs or touch-up, wipe previously installed Liquid Flashing with Sika approved cleaner to clean and reactivate the Liquid Flashing and allow to dry.
- Prime wood and concrete surfaces with Sikalastic Rapid Primer. Allow Sikalastic Rapid Primer to dry to the touch before applying Sikalastic® Rapid 724.
- If a gap of more than 1/4" (6.3 mm) exists between edge of horizontal membrane surface and vertical transition surface, the gap must be filled with Sikaflex®‐1a.
APPLICATION
- Pre-cut Sikalastic Rapid Fleece to fit around the penetration. Vertical flashing pieces must extend 2" (51 mm) from the base onto the horizontal and horizontal flashing pieces must extend 8" (20.3 cm) out from the base of any penetration. Flashing height should be a minimum of 8" (20.3 cm). Horizontal Sikalastic Rapid fleece pieces must extend a minimum of 8" (20.3 cm) beyond the leading edge of the penetration, or a minimum of 4" (10.2 cm) beyond the edge of the fastening plate. Add 2" (51 mm) for the overlap with adjoining pieces.
- Once the edges of the fleece are determined, mark a line on the membrane 1/2" (13 mm) beyond the edge of the fleece and apply painter’s tape. This will accommodate the 1/2" (13 mm) of non-reinforced Sikalastic® Rapid 724 needed to terminate to the membrane.
- With the tape in place, clean the membrane within the area using Sika approved cleaner including the plates and the penetration.
- Thoroughly stir the entire container of Sikalastic® Rapid 724 with a slow-speed (200 to 400 rpm) mechanical mixer (electric drill with a mixing blade) for two minutes.
- Pour 1 liter of Sikalastic® Rapid 724 into a clean plastic container. Add Sikalastic Rapid Catalyst to Sikalastic® Rapid 724 at rates depending on ambient temperature (see Mixing Rates table). Mix using a slow-speed mechanical mixer with a separate mixing paddle for two minutes. Once mixed, the pot life is approximately 10 - 15 minutes depending on the ambient temperature.
- Using a small ½" (13 mm) nap roller with rounded edges or 2" (51 mm) disposable paint brush apply catalyzed Sikalastic® Rapid 724 at the required consumption onto the penetration up to the finished flashing height and 2" (51 mm) onto the roof membrane.
- Embed the pre-cut vertical Sikalastic Rapid Fleece into the wet Sikalastic® Rapid 724. Use the roller or brush to eliminate wrinkles and air bubbles while completely saturating the Sikalastic Rapid Fleece. Apply additional catalyzed Sikalastic® Rapid 724 at the 2" (51 mm) overlap between the vertical Sikalastic Rapid Fleece layers.
- Apply catalyzed Sikalastic® Rapid 724 at the required consumption onto the roof membrane extending slightly onto the painter's tape. Also coat the 2" (51 mm) fingers from the vertical Sikalastic Rapid Fleece.
- Embed the pre-cut horizontal Sikalastic Rapid Fleece into the wet Sikalastic® Rapid 724. Use the roller or brush to eliminate wrinkles and air bubbles while completely saturating the Sikalastic Rapid Fleece. Apply additional catalyzed Sikalastic® Rapid 724 at the 2" (51 mm) overlap between the horizontal Sikalastic Rapid Fleece layers.
- Apply catalyzed Sikalastic® Rapid 724 at the required consumption over the entire exposed vertical and horizontal Sikalastic Rapid Fleece terminating at the finished flashing height on the vertical and onto the painter's tape on the roof. Make sure the fleece is fully saturated without any dry spots.
- Remove the painter's tape immediately after applying the final layer of catalyzed Sikalastic® Rapid 724.
Note:
Complex and/or irregular shapes including nuts, bolts, etc. may require an additional layer of catalyzed Sikalastic® Rapid 724 to ensure full coverage. Wait one hour before applications. For repairs or touch-up, wipe cured Sikalastic® Rapid 724 with Sika approved cleaner to clean and allow to dry.